Эта страница является
переводом страницы
INELS RF. Перевод выполнен на 100%.
Содержание
- 1 iRidium for INELS Wireless Control
- 2 Advantages
- 3 Setting INELS Wireless Gateway
- 4 Working in iRidium studio
- 4.1 Work with Commands and Feedbacks
- 4.1.1 General Commands and Feedback
- 4.1.2 HeatCoolArea
- 4.1.3 RF-RGB-LED-550, RFDA-73M/RGB
- 4.1.4 RF-White-LED-675
- 4.1.5 RFATV-1
- 4.1.6 RFDA-11B, RFDA-71B, RFDAC-71B, RFDEL-71B, RFDSC-11
- 4.1.7 RFGA-1
- 4.1.8 RFJA-12B
- 4.1.9 RFMD-100, RFWD-100
- 4.1.10 RFSA-11B, RFSA-61B, RFSA-61M, RFSA-62B, RFSA-66M, RFSAI-61B, RFSC-61, RFUS-61
- 4.1.11 RFSF-1B
- 4.1.12 RFSTI-11B, RFSTI-11G, RFTC-10G, RFTI-10B
iRidium for INELS Wireless Control
how iRidium server gets access to INELS Wireless network
The documentation was updated on 27.6.2022
Advantages
INELS Wireless network includes the following system components:
- eLAN-RF-003, eLAN-RF-Wi-003 - adapters of LAN TCP/IP commands to RF signal,
- RF Touch-B, RF Touch-W - touch panels with wireless interface,
- RFGSM-220M - multifunctional GSM-controller,
- RFRP-20 - RF signal repeater,
- D-Link DCS-933L/E - interior video camera.
The series of INELS Wireless devices also includes relays, switches, dimmers, thermostats, leakage sensors, electricity meters, remotes, etc.
Use eLAN-RF gateways to integrate INELS Wireless devices and iRidium.
Setting INELS Wireless Gateway
1 Enter the web-interface of eLAN-RF gateway, using admin login and elkoep password by default.
The gate gets the dynamic IP address by default, that's why a router with an activated function of DHCP server is required for the device to get an address.
2 Click the gear icon for setting.
3 Click "+" to add a new wireless device to the network. Supply power to the device (line supply or from batteries depending on the type).
4 Set the device parameters. Click the Create button.
- Product Type: type of a device,
- Address (hex): unique address of a device (6 symbols written on the body of the device),
- Label: any text to identify a device,
- Type: type of a device (not compulsory, it determines the icon of a device).
5 Click "+"to add a new room. Set the room parameters (any).
6 Click Continue. Go to the Devices tab and click on the added device to add its icon to the created room. Click Create.
7 Point a cursor to the icon of a device and a popup must appear. Remember the number - the address assigned to the device.
8 You can add all devices to the INELS Wireless network this way. If everything is set correctly, you can control wireless devices directly from the web-interface and get data from the devices.
Pay attention also to the other settings, such as the frequency of the radio signal.
Working in iRidium studio
1 Create a panel or a server project
2 Add INELS Wireless Network (TCP) driver to the project:
3 Set the driver:
- Log Level: the level of logging,
- Host: IP address of the gateway,
- Login: login to access the web-interface of the gateway (admin by default),
- Password: password to access the web-interface of the gateway (elkoep by default).
- Keep Alive: an interval to check TCP connection. In case there is no answer to the Keep Alive request, the driver state is obligatorily switched to "turned off".
4 Add a device from the list. Set the Address parameter of the device - it's the address, assigned earlier when configuring the network in the web-interface of eLAN-RF gateway.
5 All devices of the wireless network are added and set this way. Each device has its own individual address.
Work with Commands and Feedbacks
To control equipment it is required to set Commands and Feedbacks. To send a command, drag'n'drop it on a graphic item and enter a value to send. To display feedback drag'n'drop a feedback channel on a graphic item and choose how to output or display a value.
Read more about work with graphic items in the
"Types of graphic items" article.
Below you can find information about commands and feedback of INELS Wireless Control devices.
General Commands and Feedback
| Tag |
Type of tag |
Admissible values |
Description
|
| Automat |
Command Feedback |
false, true |
Activating work by schedule
|
| Battery |
Feedback |
false - low battery, true - normal |
Battery level
|
HeatCoolArea
Conditioning system
| Tag |
Type of tag |
Admissible values |
Description
|
| Correction |
Command Feedback |
from -5.0 to 5.0 °C with a step of 0.5 |
Shifts current min and max temperatures
|
| Mode |
Command Feedback |
1 - auto, 2 - holiday, 3 - manual, 4 - temporary manual |
Sets the current mode
|
| Power |
Command Feedback |
0 - off, 1 - heating on, 2 - cooling on |
Power
|
| Controll |
Feedback |
1 - auto, 2 - holiday, 3 - manual, 4 - temporary manual |
Displays the current mode
|
| Cooling |
Feedback |
false, true |
Cooling on
|
| Heating |
Feedback |
false, true |
Heating on
|
| Requested temperature |
Feedback |
From 0.0 to 32.0 °C with a step of 0.5 |
Required temperature. It is calculated on the basis of the temperature mode and Correction temperature.
|
| Temperature |
Feedback |
From 0.0 to 32.0 °C with a step of 0.5 |
Actual temperature
|
RF-RGB-LED-550, RFDA-73M/RGB
Multicolored dimmable lamp
| Tag |
Type of tag |
Admissible values |
Description
|
| Brightness |
Command Feedback |
From 0 to 255 |
Brightness
|
| Demo |
Command Feedback |
false, true |
Demo mode to change colors
|
| Blue |
Command Feedback |
From 0 to 255 |
The blue component
|
| Green |
Command Feedback |
From 0 to 255 |
The green component
|
| Red |
Command Feedback |
From 0 to 255 |
The red component
|
RF-White-LED-675
White dimmable lamp
| Tag |
Type of tag |
Admissible values |
Description
|
| Brightness |
Command Feedback |
From 0 to 255 |
Brightness
|
| White balance |
Command Feedback |
From 0 to 255 |
White balance: 0 - cold, 255 - warm
|
RFATV-1
Mechanism to control a valve
| Tag |
Type of tag |
Admissible values |
Description
|
| Open window off time |
From 0 to 60 min with a step of 10 |
Time when the valve is turned off
|
| Open window sensitivity |
Command Feedback |
0 - off, 1 - 1.2 °C, 2 - 0.8 °C, 3 - 0.4 °C |
Threshold sensitivity to temperature changes. If temperature changes within 1 minute exceed the threshold value, the valve is turned of for Open window off time period.
|
| Requested temperature |
Command Feedback |
From 0,0 to 32,0 °C with a step of 0,5 |
Required temperature
|
| Error |
Feedback |
false, true |
Error: - the valve is not mounted, - the possible movement range is too short, - the closing point is not detected
|
| Locked |
Feedback |
false, true |
Control is blocked
|
| Open valve |
Feedback |
From 0 to 100 % |
The degree of valve opening: 0 % - closed, 100 % - completely open
|
| Open window |
Feedback |
false, true |
Timer of open window state is started
|
| Temperature |
Feedback |
From 0.0 to 32.0 °C with a step of 0.5 |
Real temperature
|
RFDA-11B, RFDA-71B, RFDAC-71B, RFDEL-71B, RFDSC-11
Dimmers
| Tag |
Type of tag |
Admissible values |
Description
|
| Brightness |
Command Feedback |
From 0 to 100 with a step of 10 |
Brightness
|
| Decrease: Set time |
Command Feedback |
From 2 to 1800 sec with a step of 1 |
Time to reduce bightness from max to min
|
| Increase: Set time |
Command Feedback |
From 2 to 1800 sec with a step of 1 |
Time to increase brightness from min to max.
|
RFGA-1
Relay to open doors
| Tag |
Type of tag |
Admissible values |
Description
|
| Close |
Command |
null |
Close
|
| Open |
Command |
null |
Open
|
| Stop |
Command |
null |
Stop
|
| close |
Command |
null |
Close to an intermediate position
|
| open |
Command |
null |
Open to an intermediate position
|
| Direction |
Feedback |
"up", "down" |
Direction of motor rotation
|
| Doors |
Feedback |
1 - open 2 - open in an intermediate position 3 - closed in an intermediate positions 4 - closed |
Door position
|
| Motor |
Feedback |
false, true |
Motor is running
|
| Sensor |
Feedback |
"closed", "opened" |
State of sensor
|
| Tamper |
Feedback |
"closed", "opened" |
Sensor of motor tamper
|
| Validity sensor |
Feedback |
false, true |
State of malfunction sensor
|
RFJA-12B
Relay to control blinds
| Tag |
Type of tag |
Admissible values |
Description
|
| Roll down |
Command |
null |
Close
|
| Roll up |
Command |
null |
Open
|
| Set time |
Command Feedback |
From 2 to 240 sec with a step of 1 |
Set/get the opening/closing time.
|
| Stop |
Command |
null |
Stop
|
| On |
Feedback |
false, true |
Moving
|
| Roll up |
Feedback |
false - closed, true - open |
State of blind (tag value does not change in intermediate positions)
|
RFMD-100, RFWD-100
Motion sensors, door/window open sensors
| Tag |
Type of tag |
Admissible values |
Description
|
| Deactivate |
Command |
null |
Turn off alarm (the detector is not turned off)
|
| Disarm |
Command Feedback |
false, true |
Turn off detector
|
| Detect |
Feedback |
false, true |
Detector signal
|
| Tamper |
Feedback |
"closed", "opened" |
Sensor of motor tamper
|
RFSA-11B, RFSA-61B, RFSA-61M, RFSA-62B, RFSA-66M, RFSAI-61B, RFSC-61, RFUS-61
Relay
| Tag |
Type of tag |
Admissible values |
Description
|
| On |
Command Feedback |
false, true |
Turn on (turned on)
|
| Delayed off: Set time |
Command Feedback |
From 2 to 3600 sec |
Set the time limit to turn off
|
| Delayed on: Set time |
Command Feedback |
From 2 to 3600 sec |
Set the time limit to turn on
|
| Delay |
Feedback |
false, true |
Time counting is active
|
| Locked |
Feedback |
false, true |
Control is blocked
|
RFSF-1B
Leakage sensor
| Tag |
Type of tag |
Admissible values |
Description
|
| Detect |
Feedback |
false, true |
Detector signal
|
RFSTI-11B, RFSTI-11G, RFTC-10G, RFTI-10B
RFSTI-11B, RFSTI-11G, RFTC-10G - thermostats with a built-in sensor
RFTI-10B - 2-zone temperature sensor
| Tag |
Type of tag |
Admissible values |
Description
|
| On |
Feedback |
false, true |
Turn on
|
| Locked |
Feedback |
false, true |
Control is blocked
|
| Temperature |
Feedback |
From -99 to +99 °C, -99 °C - wire break, +99 °C - short circuit |
Temperature
|
| Temperature IN |
Feedback |
From -99 to +99 °C, -99 °C - wire break, +99 °C - short circuit |
Internal temperature
|
| Temperature OUT |
Feedback |
From -99 to +99 °C, -99 °C - wire break, +99 °C - short circuit |
External temperature
|
Links to the manufacturer's website:
https://elkoep.com