Эта страница является
переводом страницы
MILO PANEL 1W. Перевод выполнен на 100%.
iRidium for MILO PANEL 1W
Setting MILO PANEL 1W SIP Video Intercom to work with iRidium
documentation was last updated on 04.9.2023
Tested Device
| Model |
Description |
Appearance |
|
| MILO PANEL 1W |
outdoor IP video intercom |
|
Sound Quality Check on the MILO PANEL 1W Model
Technical specification of MILO PANEL 1W
| Characteristics |
Value
|
| Power supply |
12V DC
|
| Power consumption in standby mode |
250 mА
|
| Power consumption in working mode |
500 mА
|
| Screen technical specification
|
| Diagonal |
10,9 cm
|
| Format |
4:3
|
| Resolution |
480*272 pixels
|
| Contrast |
400/1
|
| Brightness |
200 cd/m²
|
| Audio
|
| Codec |
PCMA/PCMU/GSM/G722
|
| Technical specification of cameras
|
| CMOS |
colour 1/3
|
| View angle |
72º (H), 54º (V)
|
| Resolution |
1,2 megapixels
|
| Minimum illumination |
0,5 Lux
|
| Maximum conversation time |
120 sec.
|
| Response time of the electric lock release relay |
1-9 sec
|
| Delayed activation of the electric lock release relay |
0-9 sec.
|
| Door open sensor response time |
off, 30 sec, 60 sec,120 sec, 180 sec, 250 sec.
|
| Capacity of identifiers (cards) |
100 000 cards
|
| Facial recognition system capacity |
6 000 faces
|
| Working temperature |
-40 - 70 ºC
|
| Relative humidity |
20% - 80%, non-condencing
|
Connection of MILO PANEL 1W
- Connect power to MILO PANEL 1W intercom.
- Connect the SIP server to the same local network, to the same subnet (with the same mask) with your call device.
- Set up MILO PANEL 1W.
General settings of MILO PANEL 1W
Go to the web-interface and click General button.
TYPE: Select the identification parameter of the panel. There are some other parameters
related, depending on TYPE selection.
General entrance panel
Panel installed in one of the main entrances to a condominium
- PANEL №: number assigned to the general entrance where the panel is installed (1-9000). In the case that there is one entrance only, leave the default value 1
Block panel
Panel installed in a single building or in a block of a condominium.
- BLOCK: Number assigned to the block where the panel has been installed (1-999). In the case of individual blocks, let the default value: 1.
- DEVICE №: Number assigned to the block entrance where this panel is installed (1-99). In the case that there is one entrance only, leave the default value: 1.
Personal panel
It is meant for an individual apartment. You can call only this apartment.
- BLOCK: Number of the block with this apartment (1-999). In the case of individual apartments, let the default value: 1
- APARTMENT: Apartment or house number where the panel is installed (0001-9899).
- DESCRIPTION: Text to be shown in the monitor for guests.
- DEVICE №: Number assigned to this panel (1-9). In the case that there is one panel, leave the default value: 1.
DEVICE TAG: Text to be shown in the monitor and guard unit.
LANGUAGE: Select the desired language in the dropdown options:
Default option is ENGLISH.
Refresh the webpage after changing the language.
PANEL VOLUME: Select the desired value of conversation volume between 1 and 5.
The selected volume is common for outdoors and indoors.
VOICE SYNTHESISER «DOOR OPEN»: Enables or disables the speech when door lock is released. If the speech is disabled, no speech in the panel will sound when the lock is released.
VIDEO RESOLUTION: To fit the different types of monitors. The default value is 640×480.
SIP REDIRECTION MODE: This function is available for the device of sip call list. Please refer to SIP section for further details.
PARALLEL CALL: When the panel calls the resident, the monitor and all related SIP devices ring at the same time. Once one device answers the call the other one stops ringing.
SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring 30 seconds, if no answer, the call will be redirected to the related SIP device or devices that will start ringing.
DATE FORMAT: Format to show the date information in the screen.
DATE: Setting date manually (see note below).
TIME: Setting time manually (see note below).
TIME ZONE: Setting the time zone. Select local time zone and save.
Network configuration of MILO PANEL 1W
To continue working with MILO PANEL 1W, the network must be set in the following way:
1. Open the MILO PANEL 1W web interface in a web browser.
To do this, you need to access the IP address provided in the instructions, which is 10.1.0.1 by default and enter the default identification data:
- Login: admin.
- Password: 123456.
2. Click NETWORK button in the web-interface.
3. Set the IP address, subnet mask and subnet gateway available to the other used devices.
Setting MILO PANEL 1W
To make calls between iRidium panels and to call from MILO PANEL 1W intercom to i3 pro and back, SIP-server must be set correctly. To set the work of MILO PANEL 1W in the modes of SIP-server and SIP-subscriber at the same time, go to the SIP tab in the web-interface:
- Put a tick in the "ENABLE SIP" field.
- Enter IP in SIP SERVER.
- Enter the SIP USER.
- Enter the SIP PASSWORD.
SIP Calls
In the web-interface, click the SIP CALLS button
This option allows to generate calls to smartphone devices in the cases where is not a MEET monitor associated in the installation. The call can be received in 8 smartphones
simultaneously.
Furthermore, it is also possible, to generate simultaneous calls to several devices MEET
and/or third-party SIP devices as well, using SIP protocol instead of FERMAX MEET
protocol. A csv file containing the information of the diverted device or devices must be imported in the panel.
Enter numbers in the "APARTMENT" field to dial in the panel. Enter addresses of redirecting calls in the '"SIP NUMBER" field using the following format: sip:user@IP_SIP_SERVER, where user is the identificator, that the device to call has been programmed in the SIP server, and IP_SIP_
SERVER is the SIP server IP address.
ADVANCED SETTINGS
Some advanced settings, such as quick dial and directory, can be selected in this section.
QUICK DIAL: When the panel is working in 1W KEYPAD, it is possible to use the call
pushbutton in the panel to directly call to a specific device (monitor, SIP telephone,
smartphone running FERMAX MEET ME APP).
URL: Indicate the device that has to receive the call, with the corresponding format:
ONU (GPON): Used in large installations based on SIP protocol (GPON) and in combination with the configuration of said installations.
Setting of SIP Driver in i3Pro Project
- Host: IP address of the SIP server;
Port: 5060;
- Password: user password Sip;
Caller ID: user name;
SIP ID: subscriber number, this number will be assigned to the equipment on which the project will be launched;
SIP server: Another;
- Codecs used.