Remote control of iRidium pro object
General instructions on setting remote control of iRidium pro object
Available since version 1.3.6
This manual describes how to set remote control via iRidujm cloud gate.
For i3 pro to work via iRidium cloud gate Internet access is required.
Remote control via iRidium cloud gate is a
free function with the following limitations:
- The number of control panels must not exceed the license limit, and must not be more than 25 (for ENTERPRISE + license)
- The speed of data exchange must not exceed 25 kbit/s (for example, the speed of data exchange via RS-232 and RS-485 usually is about 9600 kbit/s)
What is iRidium cloud gate?
It's a cloud server of iRidium mobile company that transmits messages between panels and the server via a protected protocol. The cloud server does not store data that it transmits or know information about devices that work with it.
Advantages
- Remote control of an object without security break;
- No port forwarding
- No need to use white IP address
- The technology is easy to set.
Setting
iRidium cloud gate is available only if there is a server in the project. Both a panel and a server project have to be uploaded to the cloud.
1 Launch iRidium studio and create a new server project or open a server project that you have.
2 Go to the Config section.
3 Change the mode of server connection to connection via the gate in the Settings. To do it select Cloud Gate in the Mode field.
4 Enter the local server address in the Server Host field
5 Save the settings.
6 If you created a new project, add required drivers and set them.
7 Create a new panel project on the basis of the server project or open a panel project that you have and that is connected to the server project and synchronize it.
8 Set iRidium server driver this way:
- Mode: Cloud Gate
- Host: IP address of your server to work in the local net
9 Upload projects in the cloud, activate test mode and download projects on mobile devices.
It's absolutely necessary to download projects on panels from the cloud. Projects downloaded via iRidium Transfer do not work via Cloud gate.
Changing connection mode
You can create a combined work mode with a help of a script. When a panel is int he same net with the server, commands are sent in the local net. Then a panel and a server are in different nets, commands are sent via Cloud gate
To do it create a new script in a panel project:
IR.AddListener(IR.EVENT_START,0,function()
{
var l_sSSID = "iRidium Mobile 2 Floor WiFi";//the name of the net where your server is located.
function UpdateCloudMode()
{
if(IR.GetVariable("System.Net.SSID")!=l_sSSID)
IR.SetServerCloudConnect(true)
else
IR.SetServerCloudConnect(false)
}
UpdateCloudMode();
IR.SetGlobalListener(IR.EVENT_GLOBAL_TAG_CHANGE, UpdateCloudMode);
IR.SubscribeTagChange("System.Net.SSID");
});