ProAV Control Processor Basic
ProAV Control Processor Basic
Product code: PX-VM20-Basic
The documentation was updated on 26.12.2023
Function and Application
The device is designed for installation in automation projects for apartments, houses, buildings, apartments and commercial objects including in the decentralized Bus77 iRidi© network.
It collects, stores, processes and transmits data received via network and field interfaces.
The functionality depends on the applied software and license.
Technical Specifications
Characteristic |
Value
|
Processor |
RK3399 Rockchip 2 x Cortex-A72 2000 MHz, 4 x Cortex-A53
|
RAM |
2 Gb, DDR4
|
ROM |
16 Gb, eMMC Flash
|
Real-time clock (RTC) |
lithium battery CR1220
|
Interfaces |
Ethernet 10/100/1000 Mbps USB Type-A (USB 3.0) CAN (Bus77) KNX TP1-256 RS-485/232 (combined, up to 115 200 baud) 2 RS-232 (up to 115 200 baud) 2 universal inputs R and V (0-50kOhm, 0-12V DC) 2 low-current relays (NO, 3A, 24V DC/250VAC) 2 IR outputs IR input for the capture of IR commands (36 kHz ± 5%)
|
Power supply |
24 V DC, max 26 V DC.
The Mean Well HDR-30-24 power supply is included in the package.
It is necessary to choose a more high-performance power supply according to the PSU calculator for use with Bus77 equipment.
|
Power consumption |
max 35W
|
Operating temperature |
0 to +50 °С
|
Size (WхHхL) |
181х40x145 mm (1U)
|
Installation |
rack mountable or freestanding
|
Enclosure |
metal
|
Weight |
800 g
|
Color |
black
|
Operating system |
Linux
|
Completeness |
ProAV Control Processor PX-VM20-Basic (1 pc.), Set of screw connectors (1 pc.), Mounting kit for 19-in. rack (1 pc.), IR-emitters (2 pcs.), Power supply Mean Well HDR-30-24 (1 pc.), Passport (1 pc.), Packaging (1 pc.).
|
Warranty Оbligations
The warranty period is 24 months from the date of sale.
Without a note of sale the warranty period starts from the date of manufacture.
The manufacturer's warranty does not apply in the following cases:
- the presence of traces of mechanical damage to the device;
- moisture ingress;
- exceeding the permissible supply voltage;
- improper connection of the device;
- in cases where modifications or changes to the device or its connection schemes have by the buyer or third parties without the manufacturer's consent;
- in cases where the device is used by the buyer or third parties for purposes other than intended.
- the manufacturer's warranty does not apply in cases of non-compliance with the conditions of transportation, storage, operation, installation of the device and maintenance of the premises, as specified in this passport and operational documentation, as well as the occurrence of other circumstances beyond the control of the manufacturer.
Size
Terminals and Indication
Front panel:
|
(1) STATUS LED |
The system RGB LED is:
- red - indicates the system is loading or waiting to be loaded;
- blue - indicates the system is in recovery mode;
- green - indicates the system is in operation mode.
|
(2) KNX LED |
Behavior is determined by the application software.
|
(3) PROG push button |
Holding the button during the loading process will start the reset to default settings procedure. Other functionality is determined by the application software.
|
(4) RESET push button |
Holding the button for more than 5 seconds restarts the device.
|
(5) SERIAL LED (6) INPUTS LED (7) RELAYS LED (8) IR LED |
Behavior is determined by the application software.
|
(9) IR IN port |
IR receiver for transmitting serial IR commands (36 kHz ± 5%).
|
Rear panel:
|
(10) NETWORK port |
Ethernet port for computer network connection.
|
(11) USB port |
USB3.0 USB3.0 Type-A for optional interface converters (Zigbee. Z-wave).
|
(12) Bus77 port |
Port for power supply and CAN bus connection (Bus77). Pin sequence (left to right):
- + (24V)
- − (GND)
- CAN L
- CAN
To calculate the total power consumption and select a power supply unit, use the calculator.
120 Ohm terminal resistors must be connected at both ends of the CAN bus (included in the kit), see more details by following the link.
|
(13) KNX port |
Port for KNX bus connection TP1-256. Pin sequence (left to right):
|
(14) COM1 port |
Combined RS-232/485 serial interface. Operating modes depend on the application software:
1. RS-485 and RS-232 without HRDW Flow Control, pin sequence (left to right):
2. RS-232 с HRDW Flow Control, pin sequence (left to right):
GND - TX - RX - RTS - CTS
|
(15-16) COM2-COM3 ports |
RS-232 serial interfaces. Pin sequence (left to right): GND - TX - RX
|
(17) INPUTS port |
Universal inputs R, V (0-50kOhm, 0-12VDC). Operating modes depend on the application software. Pin sequence (left to right): GND - 1 - 2
|
(18) RELAYS port |
Low-current relays (NO, 3A, 24VDC/250VAC)
Pin sequence (left to right): 1 - А 1 - В 2 - А 2 - В
|
(19) IR port |
IR outputs for emitter connection.. Pin sequence (left to right):
1 - + 1 - − 2 - + 2 - −
Connecting complete IR emitters by cores: + - black with a gray stripe − - black
|
Features
IP address of the device by default 192.168.77.77
MAC address of the device starts with 42-77-66-xx-xx-xx
Connection to the Network and Power Supply
Installation and maintenance of the product should only be carried out by qualified specialists with compliance with safety measures.
1 Connect the ProAV Control Processor Basic to the local network with PC and router with an Ethernet cable into the Ethernet port.
2 Connect the cable from the 24VDC power supply unit to the mating part of the Bus77 (12) terminal according to polarity (left to right):
- + (24V)
- − (GND)
- not used
- not used
3 Set the mating part with the connected cable into the Bus77 terminal (12), making sure the cable connection is secure.
4 Apply the power supply.
Wait for about 30 seconds after applying power; the Status LED should light up in green.
DHCP-server must be active on the router. In case of an error in obtaining an ip address, a static address is set: 192.168.77.77.
We recommend using only 24V DC power supplies from Mean Well manufacturer.
Reset to Default Settings
To reset the ProAV Control Processor Basic to factory settings you must perform the following steps.
1 Turn off the power of the device.
2 Turn off all terminal mating parts or wires from the terminals and all connected USB devices and cables.
1 Press the Prog button on the turned off controller.
2 Holding the Prog button, supply power to the controller.
3 Hold the button Prog.
4 When the LED starts flashing, changing its color, release the Prog button.
5 After it the controller has default settings: automatic getting the IP address via DHCP is activated.
After resetting to defaults, all documents of the iRidium Server application will be deleted.
Setting Up
To set up ProAV Control Processor Basic in iRidium Studio, read the instruction by the link.